Choose the 24-frame practice set for a quick run or the 158-frame sequence to reproduce the full night. Extract your ZIP and open its folder in CAst. See the file step.
Open the example / Step 01
Enter Differential Photometry
Start here Start Citizen Astronomy (CAst). Download either AE UMa ZIP above and extract it. Keep the AE UMa practice or AE UMa full folder handy.
Under Detect & Measure, click Differential Photometry. If a different workspace is already open, choose Mode → Choose Mode… to return to this screen.
Check the count in Ready: 24 files for the practice set or 158 for the full night shown in the screenshot. If your count differs, select the extracted folder that directly contains the .fit files.
Generate a light curve / Step 05
Start the measurement
Start here The folder scan has found 24 practice images or 158 full-sequence images.
For this L-filter practice run, clear Pull Periods (1). Leave Calculate Periods, Create Measurements Table, Calibration, and Star Alignment unchecked. The folder contains science exposures with embedded sky coordinates and includes no calibration masters.
Keep Brightest Variables at 100% so you can choose AE UMa yourself. Click Generate (2). Allow the catalog lookup to finish. A first run can need internet access.
CAst opens Select Sources To Process when the list is ready. If CAst offers an existing result for this folder, opening it takes you directly to the results. The example used a saved field catalog and the images’ embedded coordinates. See the example settings to reproduce this selection.
Generate a light curve / Step 06
Check how the example was measured
Start here In the Differential Photometry workspace, choose Settings → Open Settings before starting a fresh run.
Click the Differential Photometry tab (1). The example requested 5 for Comparison Stars per Variable (2). The number that can actually be used depends on the stars in the field.
To match the brightness selection, check Use reference-star magnitude range. Set Min to the lowest allowed value (−5) and Max (3) to 16. The adaptive aperture scale was 1.60 × FWHM, which sizes the measurement circle using the width of the star image.
Click Save if you changed settings, or Cancel if you were only looking. This example used the saved catalog for the field and the embedded sky coordinates in each FITS header, without repeating the Gaia cross-check.
To measure the brightest few, set Default selection to Absolute number of brightest stars and enter a small count, such as 3 (1). Click Process Default (2).
To work by category instead, choose a category from All types (3) and narrow the list with Sources or Designation Families. Click Process All Visible (4) to measure every remaining row. A long list takes longer.
After processing, Source Results lists the measured targets. Click a row to switch the light curve to that star.
Read and check the result / Step 09
Select the measured star
Start here The reduction has finished, or you opened a cached AE UMa result.
Click Source Results (1) below the plot.
Click AE UMa (2). The workspace connects the selected source to its light curve and image. Other rows can be comparison stars used to measure the target.
Look for AE UMa in the plot title or legend. A blank graph in Standard Magnitude can mean that this filter has no usable standard magnitude. Choose the relative brightness axis in the next step.
The vertical axis now shows magnitude relative to the comparison stars. A smaller value means a brighter target relative to them. On the plotted axis, 500 × 0.001 means 0.500 magnitude. These L-filter frames can show changes in brightness without establishing a standard Johnson V magnitude.
Open the Filter list (1) beside Open and choose L for this sequence.
Turn on Show references (2) to display the comparison stars. If their traces move together with the target, inspect the images for clouds or tracking problems.
Turn on Show check (3) to include an independent check star when one was measured. For a clearer view of AE UMa alone, clear both switches.
AE UMa brightens toward the end of the run while the comparison traces remain relatively flat. The practice download provides 24 epochs. The screenshot shows measurements from all 158 original exposures.
Read and check the result / Step 12
Inspect a single frame or blink the sequence
Start here A measured target is selected and its image is visible on the right.
Click Center (1) to bring the selected star into view. Use the mouse wheel over the star if you want a closer look. The small circle is its measurement aperture.
To inspect one exposure, open the frame selector (2) and choose a filename. Watch whether the aperture still encloses AE UMa.
To play the sequence, click Blink (3). Click Blink again to pause. Look for shifts, passing clouds, or a neighboring star entering an aperture.
Changing the frame changes the filename and image. Use the measurement table to identify the exposure time and brightness for an individual observation.
The frame selector moves to the clicked observation. A trend extending over successive exposures can be compared with the reference stars; inspect a lone unusual point on its own image.
Try other comparison stars / Step 17
Keep or change the comparisons
Start hereSelect AE UMa in Source Results and choose L in the Filter list.
If the reference and check traces look steady on the scale of the target’s variation, keep the automatic result and continue to the graph or report.
To see how a different group changes the same measurements, click Scan Comps above the plot.
For this example, leave the brightness, color, and separation limits at No limit. Set Comparisons per set (N) to 3 (1). Each trial will then use three stars together.
The window moves to 2. Favourites and lists measured stars with their names, catalog brightness, and distance from AE UMa.
Try other comparison stars / Step 19
Choose which reference stars to test
Start here You have built candidates and 2. Favourites is visible.
For this small example, click Select All (1). If you saw a blended or unstable reference on the images, clear its Favourite box. Keep at least three to build a set; four or more give you alternative three-star sets.
Click a set in Combination Sets (1). Inspect the light curve, then click another set to see whether the pattern persists.
Use the preview list (2) to switch between Filter [L] and Overview (with comps). Look for stable comparisons and a target trend that survives a change of reference stars.
Choose Use Selected (3) to apply the displayed set. Choose Cancel if you want to keep your previous result.
The AAVSO Preflight Review opens. It checks which rows can go into the file format used by the American Association of Variable Star Observers and identifies missing information.
Read Rows ready for AAVSO export, Skipped measurements, and Warnings. Here 150 rows are ready for the export file and 8 were skipped. CAst lists an unmapped L filter, missing airmass, and a blank observer code. The Standard rows count alone cannot establish a Johnson V magnitude from these L frames.
Choose Cancel (1) if you need to correct the setup or revisit the reduction. To keep a local practice report after reading the warnings, click Export Anyway (2).
After export finishes, open the science folder beside the input images, then AE_UMa. Open AE_UMa_measurements.csv for the numbers. AE_UMa_accepted_observations.csv, AE_UMa_rejected_observations.csv, and AE_UMa_aavso_preflight.json document the export decisions.
The Work Log records the export paths. Saving this bundle is a local operation. Review the warnings and scientific suitability separately before submitting any observation.