CAstCitizen Astronomy All tutorials

Differential photometry

Choose the 24-frame practice set for a quick run or the 158-frame sequence to reproduce the full night. Extract your ZIP and open its folder in CAst. See the file step.

Open the example Step 01

Enter Differential Photometry

Start here Start Citizen Astronomy (CAst). Download either AE UMa ZIP above and extract it. Keep the AE UMa practice or AE UMa full folder handy.

  1. Under Detect & Measure, click Differential Photometry. If a different workspace is already open, choose Mode → Choose Mode… to return to this screen.
Mode launcher with a numbered outline around the Differential Photometry card. Enlarge screenshot
What you should see

The workspace opens with an Open button in its upper left. The curve on the launcher card is an illustration. Your own graph appears after processing.

Open the example Step 04

Select the folder containing the FITS files

Start here The folder picker is open.

  1. Select AE UMa practice for the 24-frame exercise, or AE UMa full for all 158 original frames. Choose the folder containing the FITS files.
  2. Click Choose. On Windows, the native picker may label this button Select Folder.
Directory field containing (small copy) AE UMa and the Choose button, marked 1 and 2. Enlarge screenshot
What you should see

Check the count in Ready: 24 files for the practice set or 158 for the full night shown in the screenshot. If your count differs, select the extracted folder that directly contains the .fit files.

Generate a light curve Step 05

Start the measurement

Start here The folder scan has found 24 practice images or 158 full-sequence images.

  1. For this L-filter practice run, clear Pull Periods (1). Leave Calculate Periods, Create Measurements Table, Calibration, and Star Alignment unchecked. The folder contains science exposures with embedded sky coordinates and includes no calibration masters.
  2. Keep Brightest Variables at 100% so you can choose AE UMa yourself. Click Generate (2). Allow the catalog lookup to finish. A first run can need internet access.
Workflow showing 158 loaded images, the cleared Pull Periods checkbox, 100% Brightest Variables, and Generate. Enlarge screenshot
What you should see

CAst opens Select Sources To Process when the list is ready. If CAst offers an existing result for this folder, opening it takes you directly to the results. The example used a saved field catalog and the images’ embedded coordinates. See the example settings to reproduce this selection.

Generate a light curve Step 06

Check how the example was measured

Start here In the Differential Photometry workspace, choose Settings → Open Settings before starting a fresh run.

  1. Click the Differential Photometry tab (1). The example requested 5 for Comparison Stars per Variable (2). The number that can actually be used depends on the stars in the field.
  2. To match the brightness selection, check Use reference-star magnitude range. Set Min to the lowest allowed value (−5) and Max (3) to 16. The adaptive aperture scale was 1.60 × FWHM, which sizes the measurement circle using the width of the star image.
  3. Click Save if you changed settings, or Cancel if you were only looking. This example used the saved catalog for the field and the embedded sky coordinates in each FITS header, without repeating the Gaia cross-check.
Differential Photometry settings showing five requested comparisons and a maximum reference-star magnitude of 16. Enlarge screenshot
What you should see

The resulting Scan Comps window offered four usable measured references. Catalog updates or different quality settings may change the available stars.

Generate a light curve Step 07

Measure AE UMa only

Start here The source-selection window is open.

  1. In the Sources search field (1), type AE UMa. Keep Named variables checked.
  2. Click the AE UMa row (2). Its catalog is vsx and its type is Variable. CAst chooses comparison stars for the target automatically.
  3. Click Process Selected (3). Wait for the workflow to finish measuring the images. If its progress window stays open after completion, click Close.
Source dialog filtered to AE UMa, with the search field, selected VSX row, and Process Selected button numbered. Enlarge screenshot
What you should see

The Source Results table contains AE UMa. A light curve is a sequence of brightness measurements, one for each usable exposure.

Generate a light curve Step 08

Measure several objects instead

Start here Open the source-selection window before processing.

  1. To measure the brightest few, set Default selection to Absolute number of brightest stars and enter a small count, such as 3 (1). Click Process Default (2).
  2. To work by category instead, choose a category from All types (3) and narrow the list with Sources or Designation Families. Click Process All Visible (4) to measure every remaining row. A long list takes longer.
Alternate selection routes showing the default count, Process Default, source-type filter, and Process All Visible. Enlarge screenshot
What you should see

After processing, Source Results lists the measured targets. Click a row to switch the light curve to that star.

Read and check the result Step 09

Select the measured star

Start here The reduction has finished, or you opened a cached AE UMa result.

  1. Click Source Results (1) below the plot.
  2. Click AE UMa (2). The workspace connects the selected source to its light curve and image. Other rows can be comparison stars used to measure the target.
Source Results tab and AE UMa row outlined below the light-curve panel. Enlarge screenshot
What you should see

Look for AE UMa in the plot title or legend. A blank graph in Standard Magnitude can mean that this filter has no usable standard magnitude. Choose the relative brightness axis in the next step.

Read and check the result Step 10

Switch to differential magnitude

Start here You have selected AE UMa.

  1. Open Settings (1) on the top menu bar, then move to Light Curve (2).
  2. Open the Y list (3) and choose Differential Magnitude. Click outside the menu to return to the graph.
Settings menu, Light Curve submenu and Y selector set to Differential Magnitude. Enlarge screenshot
What you should see

The vertical axis now shows magnitude relative to the comparison stars. A smaller value means a brighter target relative to them. On the plotted axis, 500 × 0.001 means 0.500 magnitude. These L-filter frames can show changes in brightness without establishing a standard Johnson V magnitude.

Read and check the result Step 11

Compare the star with its references

Start here AE UMa is selected. Use the differential magnitude axis.

  1. Open the Filter list (1) beside Open and choose L for this sequence.
  2. Turn on Show references (2) to display the comparison stars. If their traces move together with the target, inspect the images for clouds or tracking problems.
  3. Turn on Show check (3) to include an independent check star when one was measured. For a clearer view of AE UMa alone, clear both switches.
L filter, Show references and Show check marked above the real AE UMa light curve. Enlarge screenshot
What you should see

AE UMa brightens toward the end of the run while the comparison traces remain relatively flat. The practice download provides 24 epochs. The screenshot shows measurements from all 158 original exposures.

Read and check the result Step 12

Inspect a single frame or blink the sequence

Start here A measured target is selected and its image is visible on the right.

  1. Click Center (1) to bring the selected star into view. Use the mouse wheel over the star if you want a closer look. The small circle is its measurement aperture.
  2. To inspect one exposure, open the frame selector (2) and choose a filename. Watch whether the aperture still encloses AE UMa.
  3. To play the sequence, click Blink (3). Click Blink again to pause. Look for shifts, passing clouds, or a neighboring star entering an aperture.
AE UMa image pane with Center, frame selector and Blink numbered above the measured star field. Enlarge screenshot
What you should see

Changing the frame changes the filename and image. Use the measurement table to identify the exposure time and brightness for an individual observation.

Read and check the result Step 14

Confirm that the rows should load

Start here The Measurements tab shows a Load Measurements Table prompt.

  1. Check the number of rows in the message. Each exposure may contribute several rows for different stars.
  2. Click Yes to load those rows. Large tables can take a moment.
Actual table-load confirmation with Yes highlighted. Enlarge screenshot
What you should see

The prompt closes and the Measurements table fills with filenames and values.

Read and check the result Step 15

Read a measurement and its source frame

Start here The Measurements table is populated.

  1. Click a row for AE UMa. Use the File column to identify the exposure; read across the selected row for the filter and measured values.
  2. Scroll horizontally for additional columns. If a point looks unusual, compare its image with adjacent frames before deciding whether to use it.
Populated measurement table with an AE UMa measurement row marked. Enlarge screenshot
What you should see

The image and details follow the selected row. For the first AE UMa row, Diff Mag is 0.4445 and Error is 0.0060 magnitude.

Read and check the result Step 16

Trace a plotted point to one exposure

Start here The measurement rows are loaded. Select AE UMa, choose L, and clear Show references and Show check for a single trace.

  1. Click one plotted dot, such as the point outlined in the screenshot. Each dot represents AE UMa in one exposure.
  2. Read the selected filename in the frame selector. Open Measurements to inspect the matching row.
Measured AE UMa light curve with one actual observation outlined as the click target. Enlarge screenshot
What you should see

The frame selector moves to the clicked observation. A trend extending over successive exposures can be compared with the reference stars; inspect a lone unusual point on its own image.

Try other comparison stars Step 17

Keep or change the comparisons

Start here Select AE UMa in Source Results and choose L in the Filter list.

  1. If the reference and check traces look steady on the scale of the target’s variation, keep the automatic result and continue to the graph or report.
  2. To see how a different group changes the same measurements, click Scan Comps above the plot.
AE UMa workspace with Scan Comps marked beside the filter and analysis controls. Enlarge screenshot
What you should see

The comparison window opens for AE UMa · [L]. Its header gives the number of measured reference stars available to test.

Try other comparison stars Step 18

Build a pool of comparison candidates

Start here The Scan Comps window is on 1. Limits.

  1. For this example, leave the brightness, color, and separation limits at No limit. Set Comparisons per set (N) to 3 (1). Each trial will then use three stars together.
  2. Click Build Candidates (2).
Search Limits panel for AE UMa showing three comparisons per set and the Build Candidates button. Enlarge screenshot
What you should see

The window moves to 2. Favourites and lists measured stars with their names, catalog brightness, and distance from AE UMa.

Try other comparison stars Step 19

Choose which reference stars to test

Start here You have built candidates and 2. Favourites is visible.

  1. For this small example, click Select All (1). If you saw a blended or unstable reference on the images, clear its Favourite box. Keep at least three to build a set; four or more give you alternative three-star sets.
  2. Click Continue to Combinations (2).
Favourite Candidates table with its selection and Continue to Combinations buttons marked. Enlarge screenshot
What you should see

The next page lists the possible three-star sets and calculates a preview for each.

Try other comparison stars Step 20

Compare trial curves and apply a set

Start here The Favourites step has opened 3. Combinations.

  1. Click a set in Combination Sets (1). Inspect the light curve, then click another set to see whether the pattern persists.
  2. Use the preview list (2) to switch between Filter [L] and Overview (with comps). Look for stable comparisons and a target trend that survives a change of reference stars.
  3. Choose Use Selected (3) to apply the displayed set. Choose Cancel if you want to keep your previous result.
Comparison sets and a real preview curve, with the set row, preview mode, and Use Selected control marked. Enlarge screenshot
What you should see

Applying a set updates the AE UMa curve for the L filter. The Work Log identifies the comparisons used.

Save the graph or the measurements Step 21

Save the light-curve graph

Start here A light curve is visible. Select L and show the series you want in your saved figure.

  1. Click Export (1) above the plot.
  2. For a clean figure, choose Scientific (2). For the graph as it looks in the workspace, choose Theme-based (3).
Export menu above the AE UMa curve with Scientific and Theme-based marked as alternative choices. Enlarge screenshot
What you should see

The Export light curve file picker opens so you can choose where to save the figure.

Save the graph or the measurements Step 22

Name and save the plot file

Start here Choose Scientific or Theme-based in the plot Export menu.

  1. Navigate to a folder where you keep your results. With PNG selected as the file type, enter AE-UMa-L.png in the filename field (1).
  2. Click Save (2). Open your saved image and check the star name, filter, and axes.
Export light curve file dialog with AE-UMa-L.png entered and the Save button highlighted. Enlarge screenshot
What you should see

A PNG file now contains the light-curve figure. Compare the shape with the exported example below.

View the exported AE UMa light curve ↗

Save the graph or the measurements Step 24

Review the report before saving

Start here You have opened File → Export Report for AE UMa.

  1. Read Rows ready for AAVSO export, Skipped measurements, and Warnings. Here 150 rows are ready for the export file and 8 were skipped. CAst lists an unmapped L filter, missing airmass, and a blank observer code. The Standard rows count alone cannot establish a Johnson V magnitude from these L frames.
  2. Choose Cancel (1) if you need to correct the setup or revisit the reduction. To keep a local practice report after reading the warnings, click Export Anyway (2).
  3. After export finishes, open the science folder beside the input images, then AE_UMa. Open AE_UMa_measurements.csv for the numbers. AE_UMa_accepted_observations.csv, AE_UMa_rejected_observations.csv, and AE_UMa_aavso_preflight.json document the export decisions.
AAVSO Preflight Review from the actual AE UMa run with Cancel and Export Anyway marked. Enlarge screenshot
What you should see

The Work Log records the export paths. Saving this bundle is a local operation. Review the warnings and scientific suitability separately before submitting any observation.

Screenshot