The workspace opens with CLUSTER FLOW above the controls. After the filament network is ready, a glowing gas distribution appears and the simulation time begins to advance.
Pausing holds the simulated gas and its time at the current state. You can orbit or change the displayed field while it is paused. Restart rebuilds the initial gas distribution using the current Scene settings.
Open the lab and look around / Step 03
Turn the volume and look inside
Start here A live or recorded volume is visible. Pause the gas if you want to follow the same knot as the camera moves.
Place the pointer in the marked area of the picture. Hold the left mouse button, drag sideways, then release to orbit the cube.
Keep the pointer over the picture and roll the wheel to move closer or farther away. Hold the right mouse button and drag to shift a knot toward the center.
To get back to the opening view, expand View if needed, scroll the left panel, and click Reset camera.
The camera can circle the cluster even while the gas is paused. Stopping the motion keeps the current angle.
Choose what the picture shows / Step 05
Switch from density to temperature
Start here Open View in a live or replayed run. Click the Camera motion heading to collapse it if you need more room.
Click the arrow beside Display field and select Temperature. Compare the pattern with Gas density, which shows where gas collects.
If the field is too dim to inspect, move Exposure to the right a little. In the same menu, try Gas speed to see how fast gas moves or Compression / shocks to see where flows converge.
The selected field name changes in the dropdown and the picture redraws immediately. The temperature image shown here highlights a different pattern within the same gas volume. Exposure changes the image brightness.
Choose what the picture shows / Step 06
Cut a thin slab through the cube
Start here Open View and scroll the left panel until you see Slice thickness. Select Gas density under Display field to match the example.
Drag Slice thickness left from its full-width setting to about 0.40. The Slice position slider appears underneath.
Drag Slice position slowly in either direction to move the slab through the cube. To restore the whole volume, drag Slice thickness fully right.
The PNG contains the rendered gas at the viewport’s dimensions. The chosen camera angle, display field, and slice are visible in the image.
Experiment with live physics / Step 08
Change the speed of evolution and cooling
Start here Use the live Cluster flow model. Click Resume if the gas is paused. Collapse View and expand Physics.
Drag Evolution pace left to ask the solver to advance less simulated time per second. Watch the Time readout above the panel.
For a cooling experiment, note the current Cooling rate, then drag its slider a little to the right. Use the Temperature field to watch how the gas changes as time advances.
The slider readouts change immediately. Cooling affects the evolving cluster gas, so give the simulation time to show the difference. Drag a slider back to its earlier value to restore that setting.
Experiment with live physics / Step 09
Trigger one outburst
Start here Choose the live Cluster flow model and let the run advance. Expand Physics → Outbursts. The Temperature field makes local heating easier to follow.
Clear Automatic outbursts to control when the next event happens.
Check that Outflow strength is above zero. Leave the other outburst settings at their defaults for this trial.
Click Trigger outburst once and watch the gas around the two central halos over the next few simulation steps. Tick Automatic outbursts again to restore repeated events.
The preset and timestep readouts reflect the new settings. Shorter steps can take more computing time to cover the same span of simulated time.
Build a starting scene / Step 11
Set the size and detail of a cluster
Start here Use a live run. Collapse View and Physics, then expand Scene. If a recording is open, return to live first.
Set Model to Cluster flow. This model draws gas along filaments into fixed dark halos.
Drag Cluster cube size (code units) a little to the right. Read the estimated number of clumps and cell size immediately below the slider.
Open Gas grid to choose the number of cells along each side. A larger grid resolves finer structures and uses more memory. Keep the existing grid for a first run, then apply the scene.
The scene values update in the panel. As long as the change is pending, the gas in the viewport still belongs to the current run.
Build a starting scene / Step 12
Try a cube of the expanding universe
Start here In live mode, collapse View and Physics and open Scene. You can return to live from any recording.
Open Model and choose Cosmological volume. This model follows gas and dark matter as density variations grow in an expanding universe.
Inspect Comoving cube size (Mpc). Keep the displayed size for a first run, or move the slider to choose the width of the simulated region. Leave the remaining cosmology settings at their defaults.
Scroll to the bottom of Scene and click Apply scene & restart (marker 1).
Watch the amber Scene changes pending message (marker 2) disappear. Give the new grid time to appear. If Resume is showing at the top, click it to advance the new run.
The pending message disappears. The live display uses the new scene. A cluster shows Time and Box side at the top. The expanding-universe model shows Elapsed and z.
Find the marked two-line readout under the playback controls. Elapsed gives time since the starting redshift in billions of years (Gyr). z gives the redshift.
If Resume appears, click it and watch the numbers as the run advances. a is the scale factor, a measure of how far the model universe has expanded. Box gives the width in comoving megaparsecs.
As elapsed time increases, the scale factor increases and redshift falls. The example starts at z = 9 with a scale factor of 0.100.
Record, replay, or export / Step 15
Set up a short practice recording
Start here In a live run, scroll to Bake and click its heading to expand it. A bake computes a run from its starting conditions and stores selected states as frames.
Drag Evolution duration left for a short trial. The cluster example uses about 0.35 in simulation units. In the cosmological model the label shows Gyr.
Drag Cached frames near the left end to save roughly 20 states. Set Cached volume grid and Cached tracers lower for a smaller file. You can use nearby values.
Read Estimated cache before choosing a file. More frames give you more moments to replay. A larger cached grid preserves more detail in each frame.
The chosen folder contains a movie of the recording in your current view. Enabled camera rotation follows movie time during export. Stop export (keep video) finishes a shorter movie if you stop partway through.
Record, replay, or export / Step 20
Leave replay and edit the simulation
Start here A cache is open and any movie export has finished. Expand Bake and scroll below Loop replay.
Click Return to live. If you want the gas to advance, scroll to the top and click Resume if that button is showing.
Expand Scene to edit a new starting model, or Physics to change how the current live gas evolves.
The cached timeline and movie controls disappear, and the live physics and scene controls are available again. Your saved .cflow file can be reopened later.